The COVID-19 Real-Time RT-PCR Test Kit is a reliable diagnostic tool for detecting SARS-CoV-2 in respiratory samples, such as nasopharyngeal or oropharyngeal swabs. Utilizing advanced RT-PCR technology, it provides accurate results for early detection and effective management of COVID-19. Designed for use in clinical laboratories and healthcare settings, this test supports prompt diagnosis and efficient patient care. Adherence to the provided guidelines ensures optimal performance and safety.
The Human Nucleic Acid Extraction Kit (Column-Based) is a highly efficient and reliable solution for isolating DNA and RNA from human samples. Utilizing a column-based method, this kit ensures quick and effective purification of high-quality nucleic acids with minimal sample handling. Designed for use in clinical, research, and diagnostic applications, the kit offers superior performance and consistency, making it ideal for downstream processes such as PCR, sequencing, and gene expression analysis. The easy-to-follow protocol and high yield make it a valuable tool for molecular diagnostics and genomic studies.
Sensit Malaria P.f/PAN Antigen Rapid Test Kit is a qualitative immunochromatographic assay for the simultaneous and differential detection of Malaria P. falciparum and other Plasmodium (P.vivax, P. malariae, P. ovale) in human blood. The Sensit Malaria P.f/PAN Antigen test is only intended for initial screening and reactive samples should be confirmed by a supplemental assay
Sensit FSH Rapid test Kit is an in-vitro immunochromatographic assay designed for qualitative determination of FSH (follicle-stimulating hormone) produced by the pituitary gland that plays a crucial role in reproductive health in both males and females, stimulating the growth of follicles in women and sperm production in men. The test provides a visual, qualitative result, and all positive specimens are advised to be confirmed with other qualified assays.
Sensit Progestrone Ovulation Rapid test Kit is an in-vitro immunochromatographic assay designed for quantitative determination of progesterone concentration in human whole blood, serum or plasma specimen. The test is used as an aid to track ovulation, monitor the effect of progesterone therapies and in early pregnancy to help diagnose an ectopic or failing pregnancy.
Sensit IFN Rapid Test is a lateral flow immunoassay designed for the qualitative detection of interferon (IFN) in human samples. This test is intended for research or diagnostic use in detecting immune responses associated with infections, autoimmune disorders, or immune system activation. The test provides results within a short duration and is suitable for point-of-care testing
Our extensive range of urine chemistry strips offers healthcare professionals a reliable and efficient means of detecting and monitoring various health conditions. With a comprehensive portfolio of products, our urine strips provide rapid and accurate results for multiple parameters, including glucose, protein, ketone, pH, blood, and more. Designed for convenience and ease of use, our urine chemistry strips are ideal for clinical, point-of-care, and laboratory settings. Each strip is carefully crafted to ensure precise and reliable results, empowering healthcare professionals to make informed decisions and provide optimal patient care.
Product Code | Product Name | Pack Size |
---|---|---|
SU001-01 | Urine strips Glucose | 100 T |
SU001-02 | Urine strips Protein | 100 T |
SU001-03 | Urine strips Ketone | 100 T |
SU001-04 | Urine strips- Glucose & Ketone | 100 T |
SU001-05 | Urine strips Albumin and creatinine | 100 T |
SU001-06 | Urine strips- Albumin & Creatinine, Calcium | 100 T |
SU001-07 | Urine strips Protein, pH, Glucose | 100 T |
SU001-08 | Urine strips Glucose, Protein, Sp. Gravity, pH | 100 T |
SU001-09 | Urine strips Glucose, Protein, Ketone, pH, Blood | 100 T |
SU001-10 | Urine strips Glucose, protein, Ascorbic acid, pH, Blood | 100 T |
Parameter | Sensitivity | Read Time |
---|---|---|
Glucose | 2.8-5.5 mmol/L | 30 Sec |
Bilirubin | 3.3-8.6 µmol/L | 30 Sec |
Ketone | 0.5-1.0 mmol/L | 40 Sec |
Blood | 05-15 Cells/µL | 60 Sec |
Protein | 0.15-0.3 g/L | 60 Sec |
Urobilinogen | 3.2-16 µmol/L | 60 Sec |
Nitrite | 13-22 µmol/L | 60 Sec |
Leukocytes | 05-15 Cells/µL | 120 Sec |
Microalbumin | 0.08-0.15 g/L | 60 Sec |
Product Code | Product Name | Method | Description | Pack Size | Linearity |
---|---|---|---|---|---|
SC203-01 | Albumin | BCG method | Quantifies albumin in serum/plasma for assessing liver function, nutrition, and kidney disorders | 2* 50 mL, 4* 50 mL | 8 gm/dl |
SC204-01 | Bilirubin (Total & Direct) | Modified TAB method | Determines total and direct bilirubin in serum/plasma for liver function and hemolytic disease assessment | 4*50 mL | 25 mg/dl |
SC206-01 | Calcium (OCPC method) | o-Cresolphthalein complexon | Measures calcium levels in serum/plasma for bone metabolism, renal, and parathyroid disorders | 2*25 mL, 4*50 mL | 20 mg/dl |
SC207-01 | Calcium Arenazo (ARSIII) | Modified Arsenazo III method | Quantifies calcium in serum/plasma for assessing bone metabolism and kidney disorders | 4*50 mL, 2*25 mL | 20 mg/dl |
SC208-01 | Cholesterol | Modified CHOD-PAP method | Determines total cholesterol in serum/plasma for lipid metabolism and cardiovascular risk assessment | 5*10 mL, 2*30 mL, 5*50 mL, 4*50 mL, 4*100 mL | 600 mg/dl |
SC210-01 | Glucose | Modified GOD-POD method | Measures glucose in serum/plasma for diagnosing diabetes and metabolic disorders | 4*125 mL, 2*500 mL | 400 mg/dl |
SC211-01 | HDL (High-Density Lipoprotein) Precipitant | Phosphotungstate Method | Quantifies HDL cholesterol in serum/plasma for cardiovascular risk assessment | 1*40 mL, 2*40 mL | 200 mg/dl |
SC212-01 | SGOT (Serum Glutamic-Oxaloacetic Transaminase) | Modified IFCC method | Measures AST enzyme activity in serum/plasma to assess liver and cardiac function | 5*10 mL, 5*25 mL | 450 IU/L |
SC213-01 | SGPT (Serum Glutamic-Pyruvic Transaminase) | Modified IFCC method | Determines ALT enzyme activity in serum/plasma for liver function evaluation | 5*10 mL, 5*25 mL | 450 IU/L |
SC214-01 | Total Protein | Modified Biuret method | Quantifies total protein in serum/plasma for evaluating liver, kidney function, and nutritional status | 4*50 mL, 2*50 mL | 16 gm/dl |
SC215-01 | Triglycerides | Modified GPO-PAP method | Measures triglyceride levels in serum/plasma for lipid profile assessment and cardiovascular risk evaluation | 5*10 mL, 3*20 mL, 5*20 mL, 4*25 mL, 4*50 mL | 900 mg/dl |
SC216-01 | Urea Berthelot | Berthlot Method | Determines urea in serum/plasma for renal function assessment | 2*50 mL, 4*50 mL | 250 mg/dl |
SC217-01 | Uric Acid | Modified URICASE-PAP method | Measures uric acid in serum/plasma to aid in diagnosing gout and kidney disorders | 5*10 mL, 4*25 mL, 2*25 mL, 4*50 mL | 20 mg/dl |
SC218-01 | Phosphorus | Molybdate UV method | Quantifies inorganic phosphorus in serum/plasma for bone metabolism and kidney function assessment | 1* 30 mL, 2* 25 mL | 20 mg/dl |
SC219-01 | Chloride | Modified CHOD- PAP method | Determines chloride levels in serum/plasma to assess electrolyte balance and acid-base status | 2* 25 mL, 4* 50 mL | 140 mEq/l |
SC220-01 | Creatine kinase –N-acetyl-cystein (CK-NAC) | Activated Nac Method | Measures creatine kinase (CK) activity in serum/plasma for muscle damage and cardiac function assessment | 2* 10 mL, 5* 10 mL | 2000 IU/l |
SC221-01 | Creatine Kinase- MB (CK-MB) | Modified Immunoinhibition Method | Quantifies CK-MB isoenzyme in serum/plasma for myocardial infarction diagnosis | 2* 10 mL, 5* 10 mL | 1000 IU/l |
SC222-01 | Alpha Amylase | Modified CNPG2 method | Measures alpha-amylase activity in serum/plasma for pancreatic function assessment | 2* 10 mL, 5* 10 mL | 1000 IU/l |
SC224-01 | Gamma GT | Optimised IFCC Method | Quantifies GGT in serum/plasma to assess liver and biliary diseases | 2* 10 mL, 5* 10 mL | 300 IU/l |
SC225-01 | Lactate dehydeogense (LDH) | IFCC method | Determines LDH activity in serum/plasma for evaluating tissue damage and hemolysis | 2* 10 mL, 5* 10 mL | 1800 IU/l |
SC229-01 | G6PD Qualitative | Qualitative Method | Screens for G6PD deficiency in whole blood through a visual color change indicating enzyme activity | 15 Tests | - |
SC230-01 | G6PD Quantitative | Quantitative Method | Determines G6PD enzyme activity in whole blood for accurate diagnosis of enzyme deficiency | 15 Tests | - |
SC190-01 | HbA1c | Turbidimetric Method | Measures glycated hemoglobin (HbA1c) in whole blood for long-term blood glucose monitoring | 30 + 10 mL | 15% |
SC240-01 | LDL Cholesterol | Modified Liquid Clearance Method | Determines LDL cholesterol in serum/plasma for cardiovascular risk evaluation | 1* 20 mL, 1* 40 mL | 250 mg/dl |
SC241-01 | Sodium | Modified Colorimetric method | Measures sodium levels in serum/plasma to monitor electrolyte balance and hydration status | 30 * 1 mL | 180 mmol/l |
SC242-01 | Potassium | Modified STB method | Quantifies potassium levels in serum/plasma for assessing electrolyte balance and cardiac function | 30 * 1 mL | 9 mmol/l |
SC243-01 | Lipase | Methyl Resorufin Method | Quantifies lipase activity in Serum/plasma to diagnose pancreatic disorders | 12 mL, 24 mL | 250 IU/l |
SC239-01 | HDL Cholesterol Direct | Colorimetric Method | Measures HDL cholesterol in serum/plasma for cardiovascular risk assessment | 1* 40 mL, 2* 40 mL | 200 mg/dl |
IMMUNOTURBIDIMETRY | |||||
ST083-01 | RF Turbilatex | Turbidimetric method | Detects rheumatoid factor (RF) in serum/plasma for rheumatoid arthritis diagnosis | 50 ml | 160 IU/ML |
ST048-01 | CRP Turbilatex | Turbidimetric method | Measures C-reactive protein (CRP) in serum/plasma to assess inflammation and infection | 50 ml | 150 mg/L |
ST246-01 | ASO Turbilatex | Turbidimetric method | Determines ASO levels in serum/plasma for diagnosing recent streptococcal infections | 50 ml | 800 IU/ML |
Model | UNE32 |
---|---|
Sample Quantity | 32 |
Processing Volume | 60µl~1000µl |
Sample Volume | 20~500µl |
Sample Throughput | 1~32 |
Magnetic Bead Recovery | >98% |
Extracting the Difference Between Holes | CV≤3% |
Heating Temperature | 8 independent heating modules, customizable lysis and elution temperature |
Oscillating Mixing | Low, medium, and high adjustable gears |
Reagent Type | Magnetic bead open platform |
Extraction Time | 8~60min/round (depending on reagent used) |
Internal Program | 48 groups |
Program Management | Powerful program editing, USB import/export |
Safety Door Design | Auto pause when opened, resumes when closed |
Built-in Air Duct | Yes |
Ultraviolet Irradiation | Yes |
Packing Size (W*D*H)mm | 580*510*700 |
Gross Weight (kg) | 51 |
Model | UNE48 |
---|---|
Sample Quantity | 48 |
Processing Volume | 60µl~1000µl |
Sample Volume | 20~500µl |
Sample Throughput | 48 |
Magnetic Bead Recovery | >98% |
Extracting the Difference Between Holes | CV≤3% |
Heating Temperature | 8 independent heating modules, customizable lysis and elution temperature |
Oscillating Mixing | Low, medium, and high adjustable gears |
Reagent Type | Magnetic bead open platform |
Extraction Time | 8~60min/round (depending on reagent used) |
Internal Program | 50000 groups |
Program Management | Powerful program editing, USB import/export |
Safety Door Design | Auto pause when opened, resumes when closed |
Built-in Air Duct | Yes |
Ultraviolet Irradiation | Yes |
Packing Size (W*D*H)mm | 700*520*750 |
Gross Weight (kg) | 80 |
Model | UPAS101 |
---|---|
Excitation Light Source | LED |
Wavelength | Excitation wavelength λ0=365nm Detection wavelength λ1=615nm |
Detection Wavelength | λ1=615nm |
Detection Channel | 1 |
Sample Type | Serum, plasma, whole blood, urine, etc. |
Detection Mode | Supports multiple items in one card |
Testing Speed | <10s/test |
Repeatability | CV≤5% |
Stability | σ≤±8% |
Linear Correlation | (r)≥0.98 |
Accuracy | Δn≤±8% |
Display | 7-inch color touch screen |
Language | English |
Interface | RS232, USB, Ethernet port |
Printer | Built-in thermal printer |
Power Supply | 100~240V, 50/60Hz |
External Size (L*W*H)mm | 228*312*158 |
Net Weight (kg) | 3 |
Package Size (L*W*H)mm | 455*325*245 |
Gross Weight (kg) | 4.5 |
Model | UPAS112 |
---|---|
Excitation Light Source | LED |
Wavelength | Excitation wavelength λ0=365nm Detection wavelength λ1=615nm |
Detection Channel | 1 |
Incubation Position | 12 |
Sample Type | Serum, plasma, whole blood, urine, etc. |
Detection Mode | Supports multiple items in one card |
Testing Speed | <10s/test |
Repeatability | CV≤5% |
Stability | σ≤±8% |
Linear Correlation | (r)≥0.98 |
Accuracy | Δn≤±8% |
Display | 10.1-inch color touch screen |
Language | English |
Interface | RS232, USB, Ethernet port |
Printer | Built-in thermal printer |
Power Supply | 100~240V, 50/60Hz |
External Size (L*W*H)mm | 333*418*408 |
Net Weight (kg) | 17 |
Package Size (L*W*H)mm | 600*520*687 |
Gross Weight (kg) | 36.5 |
Model | UEA400 | |
---|---|---|
Measurement Channel | Vertical 8 optical channels | |
Plate Type | 96-well microplate | |
Wavelength Range | 400~750nm | |
Filter | Standard 4 wavelengths of 405, 450, 492, 630nm Standard 5 wavelengths of 340, 405, 450, 492, 630nmOptional: Up to 10 wavelengths | |
Linear Range | 0.000~3.000Abs | |
Reading Range | 0.000~4.000Abs | |
Resolution | 0.0001Abs | |
Repeatability | CV≤0.2% | |
Stability | ≤±0.003Abs/10min | |
Sensitivity | ≥0.01L/mg | |
Channel Difference | ≤0.02Abs | |
Vibration Plate Function | 3 kinds of vibration plate function, adjustable 0~255s5 kinds of vibration plate function, adjustable 0~255s | |
Incubation Function | Time Range: 0~60min Temp. Range: RT+4℃~50℃ | |
Software (Standard) | Detection Mode | Single/double wavelength |
Qualitative | Open CUT-OFF decision formula, supporting the input of judgment condition, validity condition input, grey area setting and other functions | |
Quantitative | Support linear, semi-log, natural logarithm, log-log, point-to-point, four-parameter equation and other quantitative analysis fitting algorithms | |
Others | Display | 10.1 inch color touch capacitive 10.1 inch resistive touch screen |
Operating Mode | Touch screen operation, equipped with capacitive stylus, support for external keyboard and mouse | |
Printer(Optional) | Support external USB, RJ45 network port and other universal interface printer(A4 printer can be optional) Workstation software supports normal printer(A4 printer can be optional) Workstation software supports normal printer(A4 printer and thermal printer can be optional) | |
Interface | USE2.0*4, RJ45 network port*1, RS-232*1 RS232 serial port RS-232*2(Standard RS232 to USB cable) |
|
Power Supply | AC100~240V, 50/60Hz | |
Instrument Size(W*D*H) | 450*320*300mm | |
Package Size(W*D*H) | 540*400*460mm | |
Stability | 13/15kg |
Model | UEA340 | |
---|---|---|
Measurement Channel | Vertical 8 optical channels | |
Plate Type | 96-well microplate | |
Wavelength Range | 400~750nm | |
Filter | Standard 4 wavelengths of 405, 450, 492, 630nmStandard 5 wavelengths of 340, 405, 450, 492, 630nm Optional: Up to 10 wavelengths | |
Linear Range | 0.000~3.000Abs | |
Reading Range | 0.000~4.000Abs | |
Resolution | 0.0001Abs | |
Repeatability | CV≤0.2% | |
Stability | ≤±0.003Abs/10min | |
Sensitivity | ≥0.01L/mg | |
Channel Difference | ≤0.02Abs | |
Vibration Plate Function | 3 kinds of vibration plate function, adjustable 0~255s5 kinds of vibration plate function, adjustable 0~255s | |
Incubation Function | Time Range: 0~60min Temp. Range: RT+4℃~50℃ |
|
Software (Standard) | Detection Mode | Single/double wavelength |
Qualitative | Open CUT-OFF decision formula, supporting the input of judgment condition, validity condition input, grey area setting and other functions | |
Quantitative | Support linear, semi-log, natural logarithm, log-log, point-to-point, four-parameter equation and other quantitative analysis fitting algorithms | |
Others | Display | 10.1 inch color touch capacitive screen 10.1 inch resistive touch screen |
Operating Mode | Touch screen operation, equipped with capacitive stylus, support for external keyboard and mouse | |
Printer(Optional) | Support external USB, RJ45 network port and other universal interface printer(A4 printer can be optional) Workstation software supports normal printer(A4 printer can be optional) :Workstation software supports normal printer(A4 printer and thermal printer can be optional) | |
Interface | USE2.0*4, RJ45 network port*1, RS-232*1RS232 serial port RS-232*2(Standard RS232 to USB cable) |
|
Power Supply | AC100~240V, 50/60Hz | |
Instrument Size(W*D*H) | 450*320*300mm | |
Package Size(W*D*H) | 540*400*460mm | |
Stability | 13/15kg |
Model | UEW812 |
---|---|
Cleaning Head | 8 channels and 12 channels |
Microplate Types | Four kinds, flat bottom, U bottom, V bottom, round bottom |
Average Residue | <1μl(per hole) |
Liquid Suction Time | 0.1~999.9 seconds adjustable, with an interval of 0.1 seconds |
Line Flush Time | 1~999 seconds, adjustable |
Washing Programs | Up to 200 programs |
Display | 7-inch touch display |
Liquid Injection Channels | 3(2 types of lotion and 1 type of distilled water) |
Cleaning Needle Position | 6 types(horizontal, left, middle, right, bottom, hole spacing) |
Consumption | 80W |
Power Supply | AC220V±10%, 50/60Hz; 110±10%, 60Hz |
Packing Size(W*D*H) | 720*480*400mm |
Gross Weight | 20kg |
Model | USHA500 | |||
---|---|---|---|---|
Throughput | 60 tests/hour | |||
Assay Items | 5 parts, 29 parameters, 3 histograms, 3D scattergram | |||
Principle | Tri-angle laser scatter, Flow cytometrymethod, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | |||
Test Mode | CBC mode, CBC+DIFF mode venous whole blood, Capillary whole blood and prediluted | |||
Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 4 research parameter: ALY%, ALY#, IG%, IG# | |||
Performance | Item | Linearity Range | Carry Over | CV |
WBC | 0~300*10^9/L | ≤0.5% | ≤2.0% | |
RBC | 0~8.00*10^12/L | ≤0.5% | ≤1.5% | |
HGB | 0~250g/L | ≤0.5% | ≤1.5% | |
PLT | 0~3000*10^9/L | ≤1.0% | ≤4.0% | |
Sample Volume | CBC+DIFF mode: ≤20μl CBC mode: ≤10μl |
|||
Storage | 10,000 results including histogram, scattergram and patient information | |||
Interface | 4 USB ports, 1 LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader | |||
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz; 400VA | |||
Package Size(W*D*H) | 575*490*690mm | |||
Gross Weight | 46kg | |||
Reagent Package Size | 330*330*330mm, 400*290*240mm, 400*290*240mm | |||
Reagent Gross Weight | 22kg, 2kg, 1kg |
Model | USCA200 | |
---|---|---|
Overall Performance | Throughput | 200 tests/hour |
Analysis Method | End-point, Fixed-time, Rate(Kinetic), Turbidimetry | |
Certificates | CE, FDA, ISO9001, ISO13485 | |
Overall Performance | Sample Positions | 37 sample positions |
Reagent Position | 28 reagent positions | |
Sample Volume | 2~70µl | |
Reagent Volume | 20~350µl | |
Probe | Teflon coating, with anti-collision function, liquid level detection function | |
Probe Washing | Automatic washing interior and exterior | |
Reagent Cooling | Refrigerated tray with independent switch | |
Reaction System | Temperature Control | 37±0.2℃ |
Cuvettes | 48 reusable cuvettes, optical length 6mm | |
Mixer Probe | Independent stirring | |
Washing | Automatic cuvettes washing | |
STAT Function | YES | |
Optical System | Light Source | 6V/10W halogen lamp |
Spectrophotometry | Post-spectral spectrophotometry | |
Wavelength | 340, 405, 450, 510, 546, 578, 630, 700nm | |
Absorbance | 0~3.0Abs | |
Calibration & QC | Calibration | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Logit-4P, Logit-5P |
Quality Control | Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D), Daily QC, Monthly QC | |
Data Management | Software | Windows 7/8/10, 32 or 64 bit |
LIS System | Bi-direction, support HL7 protocol | |
Interface | LAN port access | |
Printer | External optional, multiple reporting mode available | |
Working Conditions | Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 300W |
Temperature | 15~30℃ | |
Water Consumption | Deionized water:<5L/H | |
Humidity | 40%~85% | |
Size & Weight | External Size(W*D*H) | 625*425*460mm |
Net Weight | 36kg | |
Package Size(W*D*H) | 750*560*900mm | |
Gross Weight | 55kg |
Model | USCA100 |
---|---|
Sample Type | Serum, Plasma, Urine, Cerebrospinal fluid, etc |
Analytical Method | End point method, Fixed time method(two-point method), Dynamic method(rate method) |
Cuvette | Flow through a direct-reading cuvette |
Wavelength | Wavelength 340/405/450/510/546/578/630nm, 2 more open filter positions |
Wavelength Accuracy | ±2nm |
Screen | 7.0 inch LCD touch screen |
Language | English |
Printer | Built-in thermal printer |
Interface | RS-232, USB |
Consumption | 100VA |
Power Supply | AC110/220V±10%, 60/50Hz |
External Size(W*D*H) | 400*410*190mm |
Packing Size(W*D*H) | 520*490*330mm |
Net Weight | 8kg |
Gross Weight | 11kg |
Model | USUC120 |
---|---|
Principle | Photoelectric colorimetry |
Throughput | 60~120 tests/hour |
Screen | 4.3-inch touch screen |
Memory | Can store more than 2000 test reports |
Printer | Built-in thermal printer |
Interface | USB, RS232, LIS proposal |
Barcode Scanner | Can't |
Range of Application | 9, 10, 11, 14 test strip |
Items | 9 test strip: GLU, BIL, KET, pH, BLO, PRO, URO, NIT, LEU 10 test strip: GLU, BIL, KET, SG, pH, BLO, PRO, URO, NIT, LEU 11 test strip: GLU, BIL, KET, SG, pH, BLO, PRO, URO, NIT, LEU, VC 14 test strip: GLU, BIL, KET, SG, pH, BLO, PRO, URO, NIT, LEU, VC, CRE, Ca, MCA |
Power Supply | 100~240V, 50/60Hz |
External Size | 261*231*100mm |
Net Weight | 2.3kg |
Packing Size(W*D*H) | 341*296*166mm |
Gross Weight | 2.8kg |
An automated microscope integrates robotics and imaging technologies to provide efficient, high-throughput analysis of samples. These microscopes are commonly used in clinical research and diagnostics, offering automated sample loading, imaging, and data analysis. They are particularly valuable in pathology and cell biology, where large volumes of samples require detailed observation and rapid assessment.
In histology and cytology laboratories, automated slide stainers are employed to automate the staining process of tissue or cell samples on microscope slides. These devices use a series of reagents to highlight cellular structures, which are then examined under a microscope for diagnostic purposes. By automating the process, these instruments improve efficiency, reproducibility, and consistency in tissue analysis.